Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 82
Filter
1.
Santiago de Chile; Ministerio de Salud; ago 2021.
Non-conventional in Spanish | BIGG, LILACS, MINSALCHILE | ID: biblio-1517428

ABSTRACT

Proveer al equipo de salud odontológico recomendaciones basadas en la mejor evidencia científica disponible, orientada a minimizar el riesgo de transmisión de SARS-CoV-2 durante la atención odontológica generadora de bioaerosoles ambulatoria y de urgencia a nivel primario y secundario de salud: a) Usuarios que reciban atención odontológica generadora de bioaerosoles en toda la Red pública y privada de salud.b) Personal de salud que otorga atención odontológica con procedimientos generadores de bioaerosoles en sistema público o privado de salud. Profesionales de la salud responsables de la atención odontológica generadora de bioaerosoles en centros de salud públicos y privados en todos los niveles de atención y de establecimientos de educación superior. La elaboración de esta Guía de práctica clínica con metodología GRADE, se enmarca en un convenio de colaboración entre la Universidad de La Frontera y el Ministerio de Salud, en el contexto de la pandemia del COVID-19 y los múltiples desafíos en orientar a los equipos clínicos con la evidencia científica disponible al respecto.


Subject(s)
Humans , Dental Care/standards , COVID-19/prevention & control , Respiratory Aerosols and Droplets/virology , Chile , Practice Patterns, Dentists' , Dental Instruments/standards , Personal Protective Equipment
2.
Rev. Cient. CRO-RJ (Online) ; 5(3): 35-41, Dec. 2020.
Article in English | LILACS, BBO | ID: biblio-1342930

ABSTRACT

Introdução: o controle da qualidade no processo de fabricação dos instrumentos endodônticos é importante uma vez que defeitos e falhas superficiais podem comprometer o preparo dos canais. Objetivo: avaliar a presença de defeitos e falhas do processo de fabricação na superfície de instrumentos Reciproc (R25), Reciproc Blue (RB25) e XP-endo shaper (XP), por meio de microscopia eletrônica de varredura (MEV). Materiais e Métodos: Ao total, foram avaliados 60 instrumentos de níquel titânio, sendo 20 por grupo: R25, RB25 e XP, em três regiões: 0mm (ponta do instrumento), 4mm e 7mm da ponta, no MEV, com aumento de 100x. As imagens foram avaliadas quanto ao número de falhas de fabricação (bordo irregular, ranhura, microcavidade e rebarba) e por um sistema de escores de 1 a 4, sendo 1, nenhuma área com defeito e 4, mais de cinco áreas com defeitos na superfície. Os dados foram submetidos à análise estatística utilizando o teste de Dunn (p<0,05). Resultados: Sobre a análise por regiões, foram identificadas diferenças significativas em grande parte dos instrumentos. Comparando os diferentes instrumentos, não foi observada diferença significativa para microcavidade (p=0,76), bordo irregular (p=0,98) e rebarba (p=0,40). O instrumento R25 mostrou maior número de ranhuras em comparação aos demais (p=0,0000*). RB25 mostrou maiores valores de escores que os instrumentos R25 (p= 0,0002) eXP (p=0,01). Conclusão: Todos os instrumentos avaliados apresentaram defeitos/falhas superficiais do processo de fabricação.


Introduction: The quality control of endodontic instruments is extremely importantsince defects and failures on their surface, during their manufacturing process, can compromise the preparation of root canal. Objective: this study evaluated the presence of defects and failures in the manufacturing process on the surface of Reciproc (R25), Reciproc Blue (RB25) and XP endo-shaper (XP) instruments by means of scanning electron microscopy (SEM). Materials and Methods: In total, sixty nickel titanium instruments (n=20): R25, RB25 and XP were evaluated in the scanning electron microscope in three regions: 0mm (tip of the instrument), 4mmand 7mm of the tip, with a magnification of 100x. The images were evaluated in relation to the number of manufacturing faults (irregular border, groove, microcavity and burr) and by a system of scores, from 1 to 4, where 1 is no defective area and 4, more than five areas with defects on the surface. The data were submitted to statistical analysis using Kruskal-Wallis and Mann-Whitney tests (p<0.05). Results: Regarding the analysis by regions, significant differences were identified in most of the instruments. Comparing the different instruments, no significant difference was observed for microcavity (p=0.76), irregular border (p=0.98) and burr (p=0.40). The R25 instrument showed a greater number of grooves compared to the others (p=0.0000*). RB25 showed higher scores than the R25(p=0.0002) and XP (p=0.01) instruments. Conclusion: All evaluated instruments showed defects/failures in the manufacturing process.Introduction: The quality control of endodontic instruments is extremely importantsince defects and failures on their surface, during their manufacturing process, can compromise the preparation of root canal. Objective: this study evaluated the presence of defects and failures in the manufacturing process on the surface of Reciproc (R25), Reciproc Blue (RB25) and XP endo-shaper (XP) instruments by means of scanning electron microscopy (SEM). Materials and Methods: In total, sixty nickel titanium instruments (n=20): R25, RB25 and XP were evaluated in the scanning electron microscope in three regions: 0mm (tip of the instrument), 4mmand 7mm of the tip, with a magnification of 100x. The images were evaluated in relation to the number of manufacturing faults (irregular border, groove, microcavity and burr) and by a system of scores, from 1 to 4, where 1 is no defective area and 4, more than five areas with defects on the surface. The data were submitted to statistical analysis using Kruskal-Wallis and Mann-Whitney tests (p<0.05). Results: Regarding the analysis by regions, significant differences were identified in most of the instruments. Comparing the different instruments, no significant difference was observed for microcavity (p=0.76), irregular border (p=0.98) and burr (p=0.40). The R25 instrument showed a greater number of grooves compared to the others (p=0.0000*). RB25 showed higher scores than the R25(p=0.0002) and XP (p=0.01) instruments. Conclusion: All evaluated instruments showed defects/failures in the manufacturing process.


Subject(s)
Dental Instruments/standards , Endodontics/instrumentation , Microscopy, Electron, Scanning
3.
Guatemala; MSPAS. DRACES; mayo. 2019. 10 p.
Non-conventional in Spanish | LILACS, LIGCSA | ID: biblio-1224426

ABSTRACT

DRACES [Departamento de Regulación, Acreditación y Control de Establecimientos de Salud] Este documento tiene como objeto: "la Regulación, Autorización y Control de las Clínicas Dentales, en concordancia con el Reglamento para la Regulación, Autorización, Acreditación y Control de Establecimientos de Atención para la Salud, Acuerdo Gubernativo 376-2007." Es de carácter obligatorio, por lo que se aplica tanto al sector público, privado, social o subsector de la seguridad social, en todo el territorio nacional. Contiene además, las definiciones de los conceptos relacionados al tema principal, además de la infraestructura que deberá tener cada clínica, incluidos el equipo y recurso humano y técnico.


Subject(s)
Humans , Male , Female , Dental Offices/legislation & jurisprudence , Dental Offices/organization & administration , Containment of Biohazards/standards , Dental Equipment , Dental Instruments/standards , Dental Staff/standards , Guatemala
4.
Braz. oral res. (Online) ; 33: e028, 2019. tab, graf
Article in English | LILACS | ID: biblio-1001600

ABSTRACT

Abstract: This study aimed to assess the cyclic fatigue resistance of Genius and EdgeFile X1 reciprocating instruments compared with WaveOne Gold Primary. Twenty Genius (Ultradent) 25.04, 20 Genius 30.04, 20 EdgeFile X1 (EdgeEndo) and 20 WaveOne Gold Primary (Dentsply Maillefer) instruments were included in this study and tested in a static cyclic fatigue testing device, which has an artificial stainless steel canal with a 60° angle of curvature and a 5-mm radius of curvature. All instruments were operated in reciprocation mode until fracture occurred. The number of cycles to failure (NCF) was calculated and time to fracture (TF) was recorded in seconds using a digital chronometer. The mean and standard deviations of NCF and TF were calculated for each reciprocating system and the data were subjected to Kruskal-Wallis one-way analysis of variance and to Dunn's test (p < .05) using SigmaPlot software (Systat software, CA, USA). The fractured surfaces of five instruments from each brand were randomly examined and microphotographed by a low-vacuum environmental scanning electron microscopy - SEM (Tabletop Microscope TM3030, Hitachi, Japan) to confirm the cyclic fatigue fracture. EdgeFile exhibited the highest cyclic fatigue resistance, followed by both Genius files (p < .05). Within the limitations of this in vitro study, EdgeFile X1 instruments had significantly higher cyclic fatigue resistance than did Genius and WaveOne Gold Primary instruments. The cyclic fatigue resistance of both Genius files was higher than that of WaveOne Gold Primary.


Subject(s)
Titanium/chemistry , Root Canal Preparation/instrumentation , Dental Instruments/standards , Nickel/chemistry , Reference Values , Stress, Mechanical , Surface Properties , Time Factors , Materials Testing , Microscopy, Electron, Scanning , Statistics, Nonparametric , Equipment Failure Analysis , Equipment Design
5.
Braz. oral res. (Online) ; 33: e011, 2019. tab, graf
Article in English | LILACS | ID: biblio-989484

ABSTRACT

Abstract To evaluate the influence of novel ultrasonic tips as an auxiliary method for the rotary preparation of flattened/oval-shaped canals. Forty-five mandibular incisors were selected and divided into one of three experimental groups (n = 15): Group PFCP - ProDesign Logic 25/.05 + Flatsonic + Clearsonic + Prodesign Logic 40/.01; Group FCP - Flatsonic + Clearsonic + ProDesign Logic 40/.01; and Group PP - Prodesign Logic 25/.05 + Prodesign Logic 40/.05. The teeth were scanned preoperatively and postoperatively using microcomputed tomography. The percentage values for increase in volume, non-instrumented surface area, dentin removal, degree of canal transportation, and centering ratio between the experimental groups were examined. Data were analyzed using the non-parametric Kruskal-Wallis and Dunn's tests (p < 0.05). Group PFCP showed the greatest volume increase in the total portion of the root canal and the lowest percentage of non-instrumented surface area. Regarding the degree of transportation in the buccolingual direction, statistically significant differences between groups PFCP and PP were observed at the coronal third of the canal. In the mesiodistal direction, no statistically significant differences were observed at the coronal, middle, and apical thirds. As for the centering ratio, statistically significant differences were found in the buccolingual direction. In the mesiodistal direction, no statistically significant differences were observed at the coronal, middle, and apical thirds. The use of novel ultrasonic tips combined with rotary instruments in group PFCP provided a significant increase in volume and reduced the percentage of non-instrumented areas during the preparation of flattened/oval-shaped canals.


Subject(s)
Humans , Ultrasonic Therapy/instrumentation , Root Canal Preparation/instrumentation , Dental Pulp Cavity/anatomy & histology , Reference Values , Surface Properties , Microscopy, Electron, Scanning , Reproducibility of Results , Treatment Outcome , Statistics, Nonparametric , Dental Instruments/standards , Dentin/surgery , Equipment Design , X-Ray Microtomography/methods
6.
J. appl. oral sci ; 27: e20180045, 2019. tab, graf
Article in English | LILACS, BBO | ID: biblio-975882

ABSTRACT

Abstract Objective To evaluate the efficacy of different sonic and ultrasonic devices in the elimination of debris from canal irregularities in artificial root canals. Materials and Methods A resin model of a transparent radicular canal filled with dentin debris was used. Five groups were tested, namely: Group 1 - ultrasonic insert 15.02; Group 2 - ultrasonic insert 25/25 IRRI K; Group 3 - ultrasonic insert 25/25 IRRI S; Group 4 - sonic insert 20/28 Eddy on a vibrating sonic air-scaler handpiece; Group 5 - 20.02 K-file inserted on a Safety M4 handpiece. Two different irrigants (5% sodium hypochlorite and 17% EDTA) and 3 different times of activation (20, 40, and 60 seconds) were tested. Means and standard deviations were calculated and statistically analyzed with the Kruskal-Wallis and Wilcoxon tests (p<0.05). Results No statistically significant differences were found between the two irrigants used. Group 4 removed more debris than the other groups (p<0.05). Groups 1, 2, and 3 removed more debris than group 5 (p<0.05). A statistically significant difference (p<0.05) was found for the time of activation in all groups and at all canal levels, except between 40 and 60 seconds in group 4 at coronal and middle third level (p>0.05). Conclusions No significant differences were found between 5% sodium hypochlorite and 17% EDTA. When the time of activation rises, the dentin debris removal increases in all groups. Both sonic and ultrasonic activation demonstrate high capacity for dentin debris removal.


Subject(s)
Humans , Ultrasonic Therapy/instrumentation , Root Canal Preparation/instrumentation , Dental Instruments/standards , Therapeutic Irrigation/instrumentation , Reference Values , Root Canal Irrigants/chemistry , Sodium Hypochlorite/chemistry , Sonication/instrumentation , Sonication/methods , Surface Properties , Time Factors , Materials Testing , Reproducibility of Results , Edetic Acid/chemistry , Statistics, Nonparametric , Root Canal Preparation/methods , Dentin , Therapeutic Irrigation/methods
7.
Braz. dent. j ; 29(3): 249-253, May-June 2018. tab
Article in English | LILACS | ID: biblio-951547

ABSTRACT

Abstract The aim of this study was to evaluate the WaveOne Gold and One Shape New Generation systems regarding the bacterial removal from root canals infected with Enterococcus faecalis by comparing them to the conventional WaveOne and One Shape systems. Forty-eight distobuccal root canals of maxillary molars sterilized with ethylene oxide were infected with E. faecalis for 21 days, and then root canal initial bacterial sample was collected with paper cones and plated on M-enterococcus agar. The specimens were randomly divided into 4 groups according to the instrumentation: WaveOne Gold, One Shape New Generation, WaveOne and One Shape. After instrumentation, samples were collected with use of scraping and paper cones at immediate and 7 days after instrumentation. The bacterial reduction was calculated and then made intragroup analysis by Friedman test and intergroup analysis by Kruskal-Wallis with Dunn's post-hoc test, all at 5% significance. All techniques significantly reduced the number of bacteria in the root canal (p<0.05). WaveOne Gold and One Shape New Generation promoted higher bacterial reduction than WaveOne and One Shape systems (p<0.05), but no significant difference was found between WaveOne Gold and One Shape New Generation or between WaveOne and One Shape (p>0.05). Novel single-file systems promote better bacterial removal than the conventional single-file systems.


Resumo A proposta deste estudo foi avaliar os sistemas WaveOne Gold e One Shape New Generation em relação à remoção bacteriana de canais infectados com Enterococcus faecalis, comparando-os com seus sistemas convencionais WaveOne e One Shape. Quarenta e oito canais disto vestibulares de molares superiores esterilizados em óxido de etileno foram contaminados com E. faecalis por 21 dias, e então acoleta bacteriana inicial foi feita com cone de papel e plaqueadas em M-enterococcus agar. Os espécimes foram aleatoriamente divididos em quarto grupos de acordo com a instrumentação: WaveOne Gold, One Shape New Generation, WaveOne e One Shape. Após instrumentação, amostras foram coletadas utilizando limagem e cones de papel imediatamente e 7 dias após o preparo. A redução bacteriana foi calculada e então feita análise intra grupos com teste de Friedman, e entre grupos utilizando Kruskal-Wallis e teste de Dunn, todos a 5% de significância. Todas as técnicas reduziram significantemente o número de bactérias do canal radicular (p<0.05). WaveOne Gold e One Shape New Generation promoveram maior redução bacteriana que WaveOne e One Shape (p<0.05), mas nenhuma diferença significante foi encontrada entre WaveOne Gold e One Shape New Generation ou entre WaveOne e One Shape (p>0.05). Novos sistemas de lima-única promovem melhor remoção bacteriana que seus sistemas convencionais.


Subject(s)
Humans , Enterococcus faecalis/isolation & purification , Root Canal Preparation/instrumentation , Dental Pulp Cavity/microbiology , In Vitro Techniques , Pilot Projects , Dental Instruments/standards , Equipment Design , Bacterial Load , Maxilla , Molar/surgery
8.
J. appl. oral sci ; 26: e20180144, 2018. graf
Article in English | LILACS, BBO | ID: biblio-954493

ABSTRACT

Abstract Objective The aim of this study was to evaluate the influence of torsional preloading on the cyclic flexural fatigue resistance of thermally treated NiTi instruments. Material and Methods Ten new instruments New Hyflex CM (HF 30.06; Coltene/Whaladent Inc.), Typhoon CM (TYP 30.06; Clinician's Choice Dental Products) and Vortex Blue (VB 30.06; Dentsply Tulsa Dental) were chosen, based on geometry and specific characteristics of the manufacturing process. The new instruments of each system were tested in a bench device to determine their fatigue resistance through mean value of number of cycles to failure (Nf) (Control Group - CG). Another group of 10 new HF, TYP and VB instruments were submitted to 20 cycles of torsional straining between 0° and 180° (Experimental Group - EG) and then submitted to fatigue until rupture under the same conditions of the CG. Tested instruments were examined by scanning electron microscopy (SEM). Data were analyzed using one-way analysis of variance and post hoc Tukey's test (α=.05). Results Higher fatigue resistance was accomplished by HF instruments, followed by VB and TYP (p<0.05). During the torsional preloading, the lowest mean torque value was observed for TYP instruments (p<0.05). The torsional preload caused a significant reduction in the Nf values (p<0.05) of about 20%, 39% and 45% for instruments HF, VB and TYP, respectively. Longitudinal cracks, generated during the torsional preloading, were present in VB files, but were not observed in the CM instruments (HF and TYP). Conclusions In conclusion, the flexural fatigue resistance of thermally treated instruments is diminished after cyclic torsional loading.


Subject(s)
Titanium/chemistry , Dental Instruments/standards , Equipment Design/methods , Equipment Failure , Torsion, Mechanical , Nickel/chemistry , Reference Values , Rotation , Stress, Mechanical , Surface Properties , Temperature , Time Factors , Materials Testing , Microscopy, Electron, Scanning , Reproducibility of Results , Pliability , Root Canal Preparation/instrumentation
9.
Claves odontol ; 19(69): 9-16, mayo 2012. ilus
Article in Spanish | LILACS | ID: lil-688866

ABSTRACT

El objetivo del trabajo fue verificar la efectividad de procedimientos de esterilización en el instrumental de ortodoncia el objetivo del trabajo fue verificar la efectividad de procedimientos de esterilización en instrumental de ortodoncia. Seesterilizaron 10 juegos de instrumentos compuestos por alicates How recto, alicates Weingart, alicates de corte, retractores acrílicos, bastones de ligaduras elastoméricas y rollos decadenas elastoméricas. esterilización previa al trabajo: en autoclavelos alicates, en óxido de etileno los elementos plásticos y elastoméricos. Post esterilización in situ: alicates enesterilizador a bolitas de cuarzo; elementos elastoméricos y plásticos aerolizados en glutaraldehido al 2 por ciento. Se tomaron muestras con tubos de hisopos estériles, en dos momentos, 1: previo a la atención al paciente y 2: después de esterilización in situ. los tubos con turbidez macroscópica se colorearon con gram y cultivaron en medios de maC ConKey y Clde. Para cuantificar la carga microbiana, se realizaron tres siembras por estrías con ansa calibrada. momento 1: se encontrócontaminación con Corynebacterium en alicates Weingart y con Staphylococcus coagulasa negativo en los rollosde cadena.momento 2: contaminación con Corynebacterium en retractores; con Staphylococcus coagulasa negativo en alicates de corte, en retractores acrílicos, en bastones de ligadura;con Micrococcus en alicates How rectos. La presencia de cargas bacterianas no satisfactorias sugiere que los procedimientos habituales de esterilización no fueron eficaces.


Subject(s)
Sterilization/methods , Infection Control, Dental , Dental Instruments/standards , Orthodontics , Orthodontic Wires/microbiology , Colony Count, Microbial , Culture Media
10.
Dent. press endod ; 1(1): 21-27, 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-685759

ABSTRACT

A morfologia da superfície dos instrumentos TF® foi estudada utilizando estereomicroscopia e microscopia eletrônica de varredura (MEV). Ensaios mecânicos foram feitos para aferir a flexibilidade e a microdureza. Quatro conicidades de instrumentos TF® foram utilizadas (0,04;0,06; 0,08 e 0,10mm/mm). A estereomicroscopia associada com o programa AxioVision® foi utilizada para medir o ângulo da ponta, a conicidade e o diâmetro da ponta dos instrumentos. A MEV foi utilizada para identificar defeitos na superfície provenientes da fabricação e do acabamento.A flexibilidade e a microdureza foram aferidas com os ensaios de flexão e microdureza Vickers, respectivamente.A análise mostrou que o fabricante atendeu aos valores recomendados pela norma nº 28 ANSI/ADA. Os resultados da microscopia eletrônica de varredura mostraram muitos defeitos de superfície e distorção da aresta lateral dos instrumentos.Foi observado que a flexibilidade do instrumento muda com a conicidade. As forças para induzir a transformação de fase por tensão nos instrumentos com conicidade 0,04; 0,06 e 0,08mm/mm foram de 100gf, 150gf e 250gf,respectivamente. Os valores da microdureza Vickers dos instrumentos são compatíveis com os encontrados nos instrumentos fabricados pelo processo de usinagem.


Objectives: The surface morphology of TF® endodonticinstruments was studied using stereomicroscopy and scanningelectron microscopy (SEM). Mechanical tests weredone for flexibility and microhardness. Methods: Fourtapers of TF® files were used (0.04; 0.06; 0.08 and 0.10mm/mm). The stereomicroscopy associated with the AxioVision® program was used to measure the tip angle, thehelical angle, the taper and the tip diameter of the instruments.SEM was used to identify surface defects due to machiningand finishing. The flexibility and the microhardnesswere measured with bending and microhardness Vickerstests, respectively. Results and Conclusion: The analysisshowed that the manufacturer complied with the valuesrecommended by the ANSI/ADA standard number 28. TheSEM results showed many surface defects and a distortionof the instrument helix. It was observed that the instrumentflexibility changes with its taper. The forces to induce thephase transformation by stress on instruments with taper0.04; 0.06 and 0.08 mm/mm were 100 gf, 150 gf and 250gf, respectively. The values of Vickers microhardness of theinstruments are compatible with rotary instruments manufacturedby the machining process.


Subject(s)
Biomechanical Phenomena , Dental Instruments/standards , Nickel , Titanium , Torque , Torsion, Mechanical
11.
Rev. bras. odontol ; 67(2): 233-236, jul.-dez. 2010. tab
Article in Portuguese | LILACS, BBO | ID: lil-586833

ABSTRACT

O objetivo deste trabalho foi comparar a deflexão angular até a fratura e o torque máximo em torção de instrumentos endodônticos de NiTi mecanizados de um mesmo número, de um mesmo fabricante de diferentes conicidades. Os instrumentos foram submetidos ao ensaio mecânico de torção à direita. Os valores obtidos foram submetidos à análise estatística e os resultados revelaram que a conicidade das hastes helicoidais dos instrumentos ensaiados influenciaram na deflexão angular até a fratura e no torque máximo suportado pelo instrumento antes da fratura. A deflexão angular aumentou com a redução da conicidade, enquanto o torque máximo diminuiu com a redução desta.


The aim of this work was to compare the angular deflection at failure and the maximum torque of NiTi rotatory instruments with the same size, same trademark and different tapers. The instruments were submitted to clockwise torsional mechanical tests. The values were submitted to statistical analisys and the results showed that the taper of helical shaft influenced theangular deflection and the maximum torque at failure. The angular deflection increased with the taper reduction,although the maximum torque at failure decreased with the taper reduction.


Subject(s)
Biomechanical Phenomena , Dental Instruments/standards , Nickel , Titanium , Torque , Torsion, Mechanical
12.
Asunción; s.e; 20101000. 37 p. ilus.
Monography in Spanish | LILACS, BDNPAR | ID: biblio-1018732

ABSTRACT

Este trabajo tiene como juicio la conformación biomecánica de conducto radicular de conformación ovalada con la utilización de instrumentos de acero inoxidable Endo-Rez. Tecnología Endodóntica Anatómica, (Anatomic Endodontic Technology A.E.T.), es un sistema mecanizado racional, sencillo, rápido y sumamente cómodo para el paciente y que requiere de una curva de aprendizaje muy corta; permite tratamientos de resultados predecibles y repetitivos. Implica una nueva filosofía en la técnica, pues permitirá la limpieza y el modelado conservando la anatomía natural de cada conducto radicular, siguiendo la anatomía como guía, preservando la estructura dentaria. Cuando el sistema oscilatorio es usado antes de los rotatorios, un camino directo y uniforme es fácilmente creado en el interior del canal radicular. En síntesis es un sistema menos agresivo que los rotatorios, pues es lo más parecido a la instrumentación manual. El sistema oscilatorio trata de completar un sistema endodóntico, pero por desgracia no tiene muy resuelta la parte apical y transporta mucho el apice.


Subject(s)
Humans , Endodontics , Dental Instruments/standards , Dental Instruments , Dentistry , Root Canal Filling Materials , Root Canal Obturation
13.
Rev. bras. odontol ; 66(1): 82-85, jan.-jun. 2009. tab
Article in Portuguese | LILACS, BBO | ID: lil-575389

ABSTRACT

Este estudo comparou a eficácia de três aparelhos de ultrassom na remoção de retentores intra-radiculares metálicos fundidos. Utilizou-se 45 incisivos centrais superiores humanos, que receberam tratamento endodôntico e retentores (liga de Ni-Cr) fixados com cimento de fosfato de zinco. A amostra foi dividida em três grupos (n = 15), de acordo com o aparelhode ultrassom empregado (G1 = Enac OE3; G2 =JET Sonic Total; G3 = Profi III Bios) e mensurou-se o tempo de remoção (s). O teste de Tukey (5%) revelou que G3 (797s) > G1 (67,73s) = G2 (151,60s). Em G3, apenas três retentores foram removidos. Concluiu-se que G1 e G2 obtiveram igual sucesso na remoção dos retentores.


Subject(s)
Humans , Device Removal , In Vitro Techniques , Dental Instruments/standards , Ultrasonics , Incisor
14.
Rev. bras. odontol ; 66(1): 93-96, jan.-jun. 2009. tab
Article in Portuguese | LILACS, BBO | ID: lil-575391

ABSTRACT

O objetivo deste trabalho foi avaliar a influência da liga metálica na flexibilidade de instrumentos endodônticos. Foram utilizados instrumentos endodônticos de aço inoxidável e de NiTi de 25 mm de comprimento útil, conicidadede 0,02 mm/mm e de números 40 e 45. A flexibilidade dos instrumentos foi determinada por meio de um ensaio de flexão em cantilever. Com base nos resultados experimentais obtidos, pode-se concluir que entre os instrumentos endodônticos tipo K de mesmo número, os de NiTi são mais flexíveis e menos rígidos do que os de aço inoxidável.


Subject(s)
Dental Instruments/standards , Nickel , Pliability , Root Canal Preparation/instrumentation , Stainless Steel , Titanium
15.
Rev. bras. odontol ; 65(2): 234-237, jul.-dez. 2008. ilus
Article in Portuguese | LILACS, BBO | ID: lil-541833

ABSTRACT

O presente trabalho avaliou a influência da velocidade de rotação no número de ciclos necessários para fraturar instrumentos endodônticos de NiTi mecanizados. Instrumentos Protaper Universal F3 de 25mm de comprimento a 300 e 600 rpm foram usados em um canal artificial curvo. As superfícies de fratura e as hastes helicodais dos instrumentos fraturados foram analisados usando microscópio eletrônico de varredura (MEV). Os resultados indicaram que o número de ciclos requerido para causar a fratura foi influenciado pela velocidade de rotação. A morfologia da superfície de fratura apresentou característica do tipo dúctil e não ocorreu deformação plástica na haste helicoidal dos instrumentos fraturados.


Subject(s)
Dental High-Speed Technique , Fractures, Stress , Dental Instruments/standards , Nickel , Titanium , Root Canal Therapy/instrumentation
16.
Rev. Fed. Odontol. Colomb ; 71(223): 16-22, mayo-jun. 2008.
Article in Spanish | LILACS | ID: lil-541036

ABSTRACT

El tratamiento endodóntico debe garantizar la reducción o eliminación de los microorganismos que ocasionan patología pulpar. Las puntas de papel son útiles para secar el conducto antes de la obturación. Objetivo: identificar microorganismos presentes en las puntas de papel y determinar si se contaminan durante su manipulación con bacterias del ambiente o por contaminación cruzada, según cuatro protocolos diferentes de manejo. Materiales y métodos: se entregaron 6 cajas nuevas y selladas de puntas de papel Hygenic(R) a cuatro IPS para realiar el protocolo de manejo habitual. Se analizaron 26 puntas incubadas en caldo tripticasa soya, y siembra en agar tripticasa soya en presencia de turbidez, a 37º C de 24-28 horas. Las puntas se distribuyeron de la siguiente manera: control positivo: una punta de papel introducida en conducto con diagnóstico de necrosis pulpar. Control negativo: una punta de papel de caja sin destapar, manipulada en el laboratorio bajo condiciones estériles. Protocolos 1, 2, 3 y 4: seis para cada protocolo (24) se analizaron en el laboratorio. Resultados: según los diferentes protocolos propuestos para este trabajo, se encontró que en el protocolo 1 hubo contaminación en 2 cajas de puntas, se detectó presencia de S. aureus y Epidermidis. En protocolos 2, 3 y 4 no hubo presencia de microorganismos. Conclusiones: la contaminación que sufren las puntas de papel es mínima; no hubo diferencia significativa según los 4 protocolos de manejo usados en este trabajo.


Subject(s)
Biological Contamination/analysis , Dental Instruments/standards , Dental Pulp Necrosis/microbiology , Chi-Square Distribution , Clinical Protocols , Culture Media , Root Canal Preparation/adverse effects , Data Interpretation, Statistical
17.
Rev. bras. odontol ; 65(1): 12-17, jan.-jun. 2008. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-541691

ABSTRACT

Este estudo analisa a forma de trabalho, as dimensões e a resistência à flambagem de instrumentos endodônticos empregados no caterismo de canais radiculares etresiados. Foram analisados instrumentos C+File, Colorinox e Nitiflex da Dentisply-Maillefer, CC Cord da Antaeos e HI da Miltex. As dimensões foram determinadas no projetor de perfil. As formas foram obtidas no MEV. A resistência à flambagem foi quantificada pela aplicação de uma força na direção axial dos instrumentos. Concluiu-se que os instrumentos C+File apresentaram formas e dimensões diferentes. Os instrumentos C-File apresentam maior resistência à flambagem seguidos pelo CC Cord.


Subject(s)
Compressive Strength , Catheterization/instrumentation , Dental Instruments/standards , Root Canal Preparation/methods
18.
Rev. Clín. Ortod. Dent. Press ; 6(6): 64-67, dez. 2007-jan. 2008. ilus
Article in Portuguese | LILACS, BBO | ID: lil-495625

ABSTRACT

Objetivou-se com esse trabalho avaliar se há diferença na quantidade de perda de esmalte durante a remoção do compósito remanescente após a descolagem do braquete, utilizando a broca de carboneto nº 1171 em baixa e em alta rotação. Foram empregados 40 incisivos bovinos com braquetes metálicos colados com compósito em suas respectivas superfícies vestibulares. Os dentes foram divididos em 2 grupos de 20 dentes cada, de acordo com a rotação da broca utilizada para a remoção do compósito remanescente. A superfície de esmalte foi quantificada antes da colagem e após a descolagem e polimento final. Houve uma perda média de esmalte de 29,4 micrômetros no grupo que utilizou a broca em baixa rotação e de 37 micrômetros no grupo que utilizou a broca em alta rotação, sendo a diferença estatisticamente significante em nível de 1%. Concluiu-se que o uso da broca de carboneto de tungstênio nº 1171 em baixa rotação, na remoção do compósito remanescente, foi o método que acarretou menos danos à superfície de esmalte após a remoção do compósito.


Subject(s)
Cattle , Orthodontic Brackets , Dental Debonding/methods , Dental Enamel , Dental Instruments/standards
19.
Braz. oral res ; 20(2): 155-161, Apr.-June 2006. ilus, tab
Article in English | LILACS | ID: lil-432193

ABSTRACT

O objetivo deste estudo foi determinar a habilidade de corte das pontas de diamante obtidas pelo processo de deposição química a vapor (CVD) associadas ao aparelho de ultra-som no preparo cavitário minimamente invasivo. Uma cavidade padronizada foi preparada nas faces mesial e distal de 40 terceiros molares, utilizando-se pontas de diamante CVD cilíndrica e esférica. A habilidade de corte foi comparada quanto ao tipo de substrato (esmalte e dentina) e quanto à direção do movimento realizado com a ponta. As características morfológicas, a largura e profundidade das cavidades foram analisadas e medidas em microscopia eletrônica de varredura. A análise estatística pelo teste de Kruskal-Wallis (p < 0,05) revelou que a largura e profundidade das cavidades foram significativamente maiores em dentina. Cavidades mais largas foram obtidas quando se utilizou a ponta de diamante CVD cilíndrica, e mais profundas quando a ponta esférica foi empregada. A direção do movimento da ponta não influenciou o tamanho das cavidades, sendo os cortes produzidos pelas pontas de diamante CVD precisos e conservadores.


Subject(s)
Adolescent , Adult , Humans , Dental Instruments , Dental Cavity Preparation/instrumentation , Dental High-Speed Technique/instrumentation , Technology, Dental/methods , Ultrasonics , Ultrasonic Therapy/methods , Dental Enamel , Dentin , Dentistry, Operative , Dental High-Speed Technique/standards , Dental Instruments/standards , Equipment Design , Microscopy, Electron, Scanning , Statistics, Nonparametric , Vibration
20.
Rev. bras. odontol ; 63(3/4): 280-284, 2006. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-541689

ABSTRACT

No presente trabalho avaliou-se a força máxima de flexão de espaçadores endodônticos digitais de aço inoxidável e de níquel-titânio identificados pelas letras A, B, C e D, fabricados pela Dentsply - Maillefer, Suíça. Nos ensaios mecânicos de flexão, as amostras foram fixadas em uma das extremidades e a força foi aplicada na oposta (flexão em cantilever). Estatisticamente, os espaçadores endodônticos digitais de níquel-titânio são menos rígidos e mais flexíveis do que os de aço inoxidável. Para espaçadores de mesma liga metálica, a flexibilidade diminuiu com o aumento da conicidade da haste metálica.


Subject(s)
Compressive Strength , Dental Instruments/standards , Nickel , Pliability , Stainless Steel , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL